MOBIL FAST 2 MIX-MC PRO - CEMENTED MIXTURE
mobile plant for the production of structural concrete, cemented mixture and cold asphalt - continuous mixer 150 m3/h - double powder scale with load cells – conveyor belt - hot galvanised
Generic Description
- N.1 MOBIL FAST 2 MIX-MC PRO.
Mobile plant for the production of structural concrete, cemented mixture and cold asphalt - continuous mixer 150 m3/h - double powder scale with load cells – hot galvanised - N.1 POWDER DIVERTER WITH FLAP GATE - INCLUDING PNEUMATIC CONTROL.
- N.1 ANTI-OBSTRUCTION DEVICE completed with rotary paddle level-indicator device installed in the discharge cone of the loading belt.
- N.1 EURO-FLOWMIX AUTOMATION KIT FOR 2 MIX-MC PRO For batch or continuous production management - PC, PLC, LASER PRINTER and software package.
- N.1 PRINT OPTION FOR CEMENT MIXTURE AUTOMATION - for new systems.
- N.1 REMOTE TECHNICAL SUPPORT SERVICE - FREE OF CHARGE DURING GUARANTEE PERIOD.
- N.1 UPS (ON-LINE TYPE) - Battery life 6/20 minutes.
- N.1 SCREW SPEED CONTROL THROUGH INVERTER FOR MOTORS MAX 30 kW.
- N.1 COMMAND CABIN supplied by the purchasing company.
- N.1 LIFTING AND UNLOADING KIT FOR MOBILE PLANT.
- N.1 FINISHING OF PAINTED COMPONENTS STANDARD COLOUR: RAL 9002 (GREY WHITE) / RAL 7015 (SLATE GREY).
- N.1 GENERAL DESIGN SPECIFICATIONS FOR BATCHING PLANTS AND SILOS OF MAXIMUM DIAMETER 3500 mm
All the components are designed for the following environmental conditions:
- Soil roughness: flat area with low vegetation, isolated obstacles 20 times the height from the installation site - Exposition Category II (Eurocode 1);
- Actions on structures:
snow load: 1.00 kN/m2
wind load: v= 28 m/s – 100 km/h;
- Ground type: type B, medium consistency soil, average shear waves velocity in the top 30 m: between 360 m/s and 800 m/s, NSPT > 50 blows / 30 cm in coarsed-grained ground and CU,30 > 250 kPA in fine-grained grounds (Eurocode 8);
- Seismic action: peak value of assumed horizontal acceleration of the elastic response spectrum for the lifesaving ultimate limit state: ag/g = 0,20; - Outside air temperature: within -5° (minimum winter temperature) and +40° (maximum summer temperature), unless for the supply of insulated claddings on the concrete plants and/or the silos;
- Importance Class: Class I, buildings with occasional presence of people (Eurocode 1).
Steel for structural use: S275 or better quality, hot-rolled profiles, in accordance with the EN 10025 standards.
Alloy steel: S235 or better quality, in accordance with the UNI EN 10025 standards.